Partial view of the thermal oil heating plant installed
outdoors in 1992 in Hamburg sea-port .One single 120µ
coating of EVERLAST®CAROL was applied in 1996 to
the rusted flue (smoke-duct) (A).The steel chimney (B)
and the thermal oil storage tank (C) were also painted
in 1996 with a blue anticorrosion single-coat and an
aluminium anti-rust-paint respectively.
After 5 years service in an acidic and seawater
moisturized industral air, only the EVERAST®CAROL
coating is in flawless and elastic condition. While the
conventional coatings(C)and (B) became brittle and failed
to rust-protect the steel by loss of adhesion
EVERLAST® CAROL is still elastic and there are no
rust-spots, no peeling and no blisters on the coating
surface.The exhaust gas temperature in the flue reaches
350 deg Celsius (650 deg Fahrenheit).
|
|
Teilansicht der 1992 im Hambuger Hafen im
Freien aufgestellten heizölgefeuerten Wärmeölanlage.
1996 Auftrag von 120µ EVERLAST® CAROL, direkt
auf die rostige Rauchgasleitung (A) aus Stahlblech. Der
Stahlschornstein (B) sowie der Thermalölvorratstank(C)
wurden im gleichen Jahr mit einem blauen Einschichter
bzw. mit einem Aluminiumkorrosionschutzlack
gestrichen.
Nach 5 Jahren Bewitterung und 14000 Betriebstunden in
feuchter, saurer seewasserhaltiger Industrieluft ist
lediglich die EVERLAST®CAROL Beschichtung noch
in einwandfreiem Zustand. Während die Beschichtungen (C) und(B) versprödeten und durch Haftungsverlust im Rostschutz versagten blieb EVERLAST®CAROL elastisch und festhaftend, Die Abgastemperatur im
Rauchgasrohr (A)beträgt 350 Grad Celsius!
|
|